When using the function that always keeps the latest data file on the card Media FIFO and the number of files in the same directory exceeds , CF card deletes the old data file and saves new one even if there is free space on the card. Is there a warning when the CF card starts running out of free space? There may be a problem with the CF card. Try the following. Eject, then reinsert the CF card. Replace the card. Reformat the card on the DX. Can I eject the CF card during recording?
Yes, if the CF card is not being accessed. Do you carry any CF cards that have been operationally validated? What happens when transferring files via FTP? When the CF card becomes full, files continue to be created in the internal memory. The files created in internal memory are also transferred via FTP.
Is report data saved on the CF card? As with recorded data, files are saved to the CF card after being created in internal memory if the auto save function is ON. Hourly reports are saved every hour, and daily reports are saved every day.
Viewer: You can display measured data as trends or numeric values, and print them. Hardware configurator: You can create settings files for a Can I display and analyze recorded data on a PC? Can you tell me what user's manual or software CD is included in the packaging upon delivery? Separately purch Is a warranty card included? The warranty is handled with the DX serial number, so a printed warranty card is not included.
The warranty period is one year from date of purchase. Do I need additional software to create custom display screens? You can create them by using keys on the main unit, but it is much easier by using DAQStudio. Which compact flash cards CF cards have been validated? Consider upgrading to the latest version. You can download the latest version by using the following link. By using the main unit FTP server function, can I acquire recorded data files from the main unit CF card or internal memory onto a PC on a local area network?
What are the supported e-mail authorization methods? Can I adjust the main unit time during recording? Yes, you can adjust it directly on the main unit even during recording. If you adjust the time during recording, the acquired data is time-stamped with the new time. The data list doesn't appear in the web server screen. The following conditions must be met in order for the data list to appear in the web server screen. Login via communication must not be set.
Note that the data list never displays on models with the advanced se What happens if I mis-enter the user ID and password multiple times? You can set the number of password retries to 3, 5, or unlimited default is 3. When the number of retries is exceeded, the unit is locked. Service is required to clear the lock, so please manage user IDs and passwords with care.
Note that if 1 unit Connect the PC and DX via a hub. Check the PC's IP address and subnet mask using the ipconfig command. Check the DX's IP address and subnet mask i How do I wire the terminals and what is the diameter of the terminal screws?
For terminal wiring, see the section on grounding and wiring in the operation guide. See chapter 3, "Viewing Recorded Data " in the operation guide. For further details, see the viewer's user's manual. DXA user's manual If a power failure occurs while reports are being created, is the report up to the failure created?
No, but the creation of the report restarts after recovery from the power failure. The operation is different depending on whether the recovery time is before or after the report creation time has elapsed.
For details, see "Special Data Handling How do I change the measured data interval recording interval? You can tell which type the data is by looking inside the blue band in the upper part of the screen. In the case of 2 DISP display data , the sampling interval changes i Can I automatically convert recorded data files to Excel?
With DAQManager, you can specify the folder containing the recorded data files as the auto-import destination, then set it for automatic conversion to Excel.
Note that this is not supported with addition of the advanced security option suffix c You can receive settings by using the user management "Monitor" function specific to advanced security. The Monitor function enables up to 2 connections. When 2 Monitor functions are connected on the network, you can receive settings. Yes, note that the passwords in the account information will be initialized. Can I compare settings?
For details, see section 1. We have a special license number available in case of lost licenses. See the following URL. You can use the Windows telnet command. At the command prompt, type "telnet.
What should I do about this? Communication could not be established with the FTP server. You can check details on codes in the FTP log screen. In the operation menu on the left side of the screen, m During recording the following error appeared: "E Insufficient free space on media.
If the CF card does not have sufficient free space, or if there are files or more, old files will be overwritten with new ones. Is there any way to clear those trigger marks?
For details, see section 2. User's manual download How can I display it? If assigned to multiple channels, display the trip line of the active waveform. Click the color bar on the left side of the viewer, and activate the waveform of the channel on which you set the trip line. The number of licenses is 1.
It is not a matter of insufficient space for the folder contents, or another program accessing the contents. My OS is Windows 7. Check your Windows 7 rights. If you don't have write permission, change your permissions. My user name, ID, and password are correct, and I confirmed my signature privileges on the main unit. It is possible that the user has expired and the password has returned to the default, or some similar problem.
See section 2. The first command is accepted, but I get no response from any subsequent command even the same one as the first command. What could be the problem? Some commands are sent in units of words. This always results in an even number of bytes. Can I use encrypted USB memory? After starting recording with a remote signal, if I accidentally press the stop key, does recording continue or stop? After starting with a remote signal, if you press stop, a confirmation message appears.
If you select to stop recording, it stops. If you use key lock on the stop key, recording won't stop even if you accidentally press the stop key during record Also, if you lost your license number, please see "Universal keys in case of lost licenses. Can I expand the trend display area by narrowing the upper and lower limit of the scale?
If you narrow the lower and upper-limit values, change the lower and upper-limit values of the span accordingly. In the DXAdvanced series, there is no bias function for adding or subtracting a specific value to or from the input value. How can I display the measured temperature as 0. In the input range settings, you can add a specific value in the same manner as a bias setting by selecting a scale.
To display the temperature 0. There are two locations, one on the front and one on the back. On the front, it's inside the front panel door next to the CF card slot.
On the back, it's next to the Ethernet interface. Is there anything I need to be careful of? With the DX, you cannot use communication channels. In what cases does an overrange occur? The conditions under which an overrange occurs depends on the input range mode settings. For details, see the note under "Digital Display" in section 1. Can I check the Modbus operation status? When registering a system administrator in the user registration screen, it only lets me set the "Default Password.
In the user registration screen, first set the default password. The first time you log in, enter the default password. The message, "Your password has expired. Key in your new password" appears, and you can enter a new password. For more i What is the difference between these two? With memory sampling output, the relay is energized on memory start, and deenergized on memory stop.
With the output device information on memory stop setting, the relay is energized when you stop memory sampling. These actions cannot be changed.
How can I copy data in internal memory to the USB memory? In the User's Manual, see section 2. Can I use output from a differential pressure transmitter as input, and then perform square root computation? When logging in, I entered the wrong password several times, and the user locked icon appeared. How can I log in? See "Dealing with the Invalid User Status" in section 2.
If all system administrator passwords are invalidated, please contact your Yokogawa servi The interval of the high limit on rate-of-change alarm and lower limit on rate-of-change alarm is determined by multiplying the scan interval by the number of times sampled. Where do you set the scan interval?
For details, see section 3. Q: With RTD input, the input source resistance is described in section The boundary value is the position on that range, expressed as a percentage, that divides the compressed and expanded display areas. When I split the screen in 2, I can't display the current trend and historical trend at the same time. What should I do? I'm using event data. The procedure you mentioned can only show historical trends of display data.
It won't work with event data. How many amperes should I select for the DXAdvanced series power supply circuit breaker? This will be the same as the switch specifications in the operation guide. I set temperature and pressure to a single group in the display group channel settings. How can I display the scales of both temperature and pressure? Set the scale positions separately for temperature and pressure. If the scales of multiple channels are se How do I calculate the overall accuracy?
In one month, the daily report file is completed. One RJC temperature sensor is included with each input terminal block. I entered the Tag No. The keyword for tag no. You can display blue and black measured values in the historical trend display. Which values are being displayed? Can I omit parameters when using record template keywords? Can I view files that are undergoing memory sampling on a PC?
If you view the memory summary, "Sampling" is displayed for the factor. It will provide a detailed explanation of the Advanced Alarm Reporter functions.
The functions described in this paper were first released in Print Wave version 5. As groups of sensors in the field became intelligent and capable of handling not only simple data, but also so-called "information" with added values such as error detection and statistical analysis, recorders became required to play a role in transmitting such information.
Resources Downloads. Request a Quote. Notice: This product was discontinued on Jan 1, Application Note. Food Packaging with the DXP. Overview: A leading manufacturer of high shear fluid processors was looking for a solution to provide secure, stable pressure readings. White Paper. Yokogawa Technical Report. Overview: As groups of sensors in the field became intelligent and capable of handling not only simple data, but also so-called "information" with added values such as error detection and statistical analysis, recorders became required to play a role in transmitting such information.
Can I perform pulse calculation? Please see your nearest sales representative. For relative time, set the time until the end of the interval — For absolute time, set a reference time, then select an interval from the following. There are hourly, daily, weekly, and monthly reports, and you can write average, max, min, and integral values to internal memory. I'm looking for a substitute product for a discontinued model. Please see the following page for recommended replacements for discontinued models.
Information on discontinued products and recommended substitute models. Also, can the CF card be formatted on a PC? It supports CF cards of up to 2 GB. Try switching to a medium with more free space, or use the PC to delete files on the medium and make more free space. Can I view a list of alarm occurrences? During memory sampling, there is an alarm summary. You can display a history of up to alarms. When does FTP transmission occur? Are past data also transferred?
Files are transferred when they are created at the auto save interval or other intervals. Files created in the past are not sent, but if some files fail to transfer due to network-related or other problems, those files are sent along with the latest With display data, how do I set it up so that on an autosave of once per day it saves data from —? Set the autosave interval to 1 Day, the memory timeup to Day, and the hour to 0.
Display data. Probably your trigger settings are not correct. For details, see the following. Display and event data files I'm recording display data at a scan interval of msec. If I open the files in the viewer the data interval is 0. The fastest save interval for display data is 0. If you want to save the data at msec intervals, you'll need to use event data.
Display and event d With display data recording, if I set autosave in units of 1 day, from what data to what data constitutes "1 day"? Note that if you're also using the memory timeup function, you can start a new file at, for example, 00 hours and record 1 day's worth thereafter. On the operator page, you can switch screens from a web browser. You cannot switch screens on the monitor page.
However, you cannot access the files in internal memory. Yes, by using the Web server display function. What is the screen update interval when monitoring screens on the web? The update interval of the web monitor page is approximately 30 seconds.
What are the data types that can be sent via FTP? Why are there 1—4 alarms per channel? Four alarms levels can be set per channel. You can also set the same type of alarm for different levels. Why are there 2 data values max and min for acquired data? Because the data type is set to display data. Display data is saved as the maximum and minimum values measured in the scan interval within the sampling interval.
Using display data, how can I change the data save interval? To change the save interval for display data, change the display update interval. Can I receive email notification of alarm occurrences? Yes, with the email transmission function. When an alarm occurs, mail is sent to the specified email address. What are the sizes of display and event data?
What is the difference between event data and display data? Event data are the instantaneous values recorded at each scan interval. Display data are the maximum and minimum sampled values recorded within the display update time. I can't set a temperature range of 0. What is the allowable setting range for scaling? Omitting the decimal point, the values that can be set for scaling are to In this case, set it to "0.
The display of the scale setting upper limit value just automatically goes back 2 decimal places. The decimal place is determined by the scale lower limit value setting.
Set the decimal place in the scaling lower limit value. Can I view past display data? Using the Historical function, you can view a historical display of data in internal memory or external media.
What is the display update interval for recording display data at 1 minute intervals? Display and event data files. What is Event data? Event data are the instantaneous values recorded at each sampling interval.
They can be recorded at faster intervals than display data, and can therefore are used for analysis in greater detail. Is alarm information recorded to a file? What information is displayed in alarm summaries? The channel on which the alarm occurred, the time, and other information. Can I set alarms beyond the span setting range? Is there a way to delay occurrence of alarms?
Yes, there is an Alarm Delay function.